GE Industrial Solutions Pulsar Plus Controller User Manual

The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear in this document.

© 2011 Lineage Power All International Rights Reserved Printed in U.S.A.

Pulsar Plus Controller Family

Table of Contents

Table of Contents . 3 Table of Figures . 5 Table of Tables . 6 Introduction . 9 Pulsar Plus Family Controllers . 9 Key Features . 9 Applications . 11 Product Description . 13 Overview . 13 Configurations . 14 Getting Started – Installation, Start-Up, and Basic Configuration . 17 Preparation . 17 Install and Configure Slot/Door-Mount Controllers . 18 Install and Configure Pulsar Plus NE843G Controller . 23 Connect To the Controller . 29 Initial Startup of the Controller . 43 Basic Controller Configuration. 44 Web Interface . 47 Controller Operation . 53 Overview . 53 Front Panel Controls and Status Display - Pulsar . 54 Front Panel Controls and Status Display - Phoenix . 57 Audible Alarm . 60 Voltage Test Jacks . 61 Local and Remote Access Ports . 62 Front Panel Menu Structure . 63 Status . 70 Control/Operations . 74 History . 76 Configuration . 77 10/100 Base-T Port . 89 Optional Devices and Modules . 93 One-Wire Peripheral Devices . 93 NE872A Distribution Monitor and Control Module . 100 QS871A Distribution Monitor and Control Module . 105 ES772A Remote Distribution Module . 109 Troubleshooting . 119 Specifications . 123 Safety . 127 Safety Statements . 127 Warning Statements and Safety Symbols . 128 Precautions . 129 Contacts and Warranty . 131 Customer Service Contacts . 131 Product Warranty . 131 Appendix A: Software Upgrades through Craft Port . 133 Appendix B: T1.317 Command Language . 139 Issue 7 December 2011 3

Pulsar Plus Controller Family Initializing Controllers . 139 T1.317 Command Language . 140 Appendix C: Battery Functions. 163 Float Mode . 163 Slope Thermal Compensation . 163 Plant Battery Test . 166 Boost Mode . 167 Appendix D: Default Configurations . 171 Appendix E: Alarms and Relays . 185 Alarm Relays . 185 Alarms . 185 Appendix F: SNMP . 191 Issue History . 195 Issue 7 December 2011 4

Pulsar Plus Controller Family

Table of Figures

Figure 1: Infinity NE and P2 Power Systems . 11 Figure 2: Compact Power Systems . 12 Figure 3: General Power System Block Diagram . 13 Figure 4: Generic Block Diagram of Pulsar Plus NE843A Controller . 14 Figure 5: Front Panel Display . 53 Figure 6: front Panel - Pulsar . 54 Figure 7: Front Panel - Phoenix III . 57 Figure 8: Status Menu . 66 Figure 9: Control / Operations and History Menus . 67 Figure 10: Configuration Menu (part 1) . 68 Figure 11: Configuration Menu (part 2) . 69 Figure 12: QS873A Voltage/Thermal Probe (VT-Probe) . 93 Figure 13: VT-Probe Connections To Infinity NE . 94 Figure 14: ES771A Remote Voltage Monitor Module . 96 Figure 15: Four-String System Monitored For Imbalance With One VT Probe Per String . 98 Figure 16: Same System Monitored For Imbalance With VT Probe On Every Battery . 99 Figure 17: NE872A Remote Distribution Module . 101 Figure 18: NE872A ID Jumper Settings . 103 Figure 19: NE872A ID Jumper Settings . 103 Figure 20: QS871A Remote Distribution Module . 105 Figure 21: ES772A Remote Distribution Module . 109 Figure 22: Typical Alarm Connections . 112 Figure 23: Alarm Connections with Reverse Polarity Protection . 113

Figure 24: Reverse Polarity Protected Alarm Connections with an External Battery Disconnect Switch 114

Figure 25: Alarm Connections for DIN Style Load Protectors . 115 Figure 26: ES772A Mounting Hole Locations . 116 Figure 27: J5694722 External Distribution . 116 Issue 7 December 2011 5

Pulsar Plus Controller Family

Table of Tables

Table 1 Pulsar Plus Controller Family Product Options . 16 Table 2 Controller Standard Defaults Door Mounted . 21 Table 3 Table 2 Controller Standard Defaults NE843G . 27 Table 4 Auxiliary Input Connector . 32 Table 5 Output Alarm Connector . 34 Table 6 Local RS-232 Serial Port Signals . 37 Table 7 Power And Sense Connector . 38 Table 8 Status LEDs - Pulsar . 56 Table 9 Status LEDs - Dedicated - Phoenix . 58 Table 10 Status LEDs - Custom Assignable - Phoenix . 58 Table 11 Rectifier Status . 70 Table 12 Converter Status . 70 Table 13 Batteries Status . 71 Table 14 Shunt Currents Status . 71 Table 15 Disconnect States Status . 71 Table 16 Alarm Thresholds Status . 72 Table 17 Enabled/Disabled Info Status . 72 Table 18 Network Settings Status . 73 Table 19 System Info Status . 74 Table 20 Control/Operations . 74 Table 21 History . 76 Table 22 Float Settings Configuration . 77 Table 23 Shunt Monitors Configuration . 78 Table 24 Shunt Type Configuration . 79 Table 25 Rectifiers Configuration . 81 Table 26 Batteries Configuration Table 27 Contactors Configuration . 84 Table 28 Disconnects Configuration . 84 Table 29 Converters Configuration . 85 Table 30 Boost Configuration . 86 Table 31 System Settings Configuration . 88 Table 32 Communication Ports Configuration . 88 Table 33 NE872 J1 Signal Description . 103 Table 34 NE872 J2 Signal Description . 104 Table 35 NE872 TB1 Signal Description . 104 Table 36 NE872 J100 and J101 Signal Description . 105 Table 37 QS871 J1 Signal Description . 107 Table 38 QS871 J2 Signal Description . 108 Table 39 QS871 J3 Signal Description . 108 Table 40 QS871 J100 and J101 Signal Description . 108 Table 41 ES772 Connector J1 Pinout Definitions . 112 Table 42 ES772 Connector J3 Pin Definitions . 112 Table 43 Auxiliary Port Connector Signals . 115 Table 44 Infinity NE System Troubleshooting . 119 Table 45 Specifications . 123 Table 46 T1.317 Power System Related Commands . 140 Table 47 T1.317 User Login Related commands . 142 Issue 7 December 2011 6

Pulsar Plus Controller Family Table 48 T1.317 DC Plant Related Commands . 142 Table 49 T1.317 Alarms With Two Thresholds Related Command . 142 Table 50 T1.317 Alarms With One Threshold Related Command . 143 Table 51 T1.317 Alarms With No Threshold Related Command . 144 Table 52 T1.317 Rectifier Management Related Commands . 145 Table 53 T1.317 Rectifiers Related Commands . 145 Table 54 T1.317 Converter Plant Related Commands . 146 Table 55 T1.317 DC Converter Related Commands . 147 Table 56 T1.317 Battery Reserve Management Related Commands . 147 Table 57 T1.317 Battery Type Definition Related Commands . 148 Table 58 T1.317 Boost Management Related Commands . 148 Table 59 T1.317 Disconnect Contactor Control Related Commands . 148 Table 60 T1.317 Distribution Current Monitor Related Commands . 149 Table 61 T1.317 Distribution Contactor Interface Related Commands . 149 Table 62 T1.317 Slope Thermal Compensation Related Commands . 149 Table 63 T1.317 Input Management Related Commands . 150 Table 64 T1.317 Call-Out Manager Related Commands . 150 Table 65 T1.317 Call-Out Phone Number Related Commands . 151 Table 66 T1.317 Call-Out Email Address Related Commands . 151 Table 67 T1.317 SNMP Destination Related Commands . 151 Table 68 T1.317 Periodic Call-Out Related Commands . 151 Table 69 T1.317 Modem Related Commands . 151 Table 70 T1.317 Local RS-232 Port Related Commands . 152 Table 71 T1.317 Alarm Test Related Commands . 152 Table 72 T1.317 Alarm Cut-off Related Commands . 153 Table 73 T1.317 User Defined Events Related Commands . 153 Table 74 T1.317 Derived Channels Related Commands . 153 Table 75 T1.317 Trend Related Commands . 154 Table 76 T1.317 TL1 Manager Related commands . 154 Table 77 T1.317 TL1 Object Related Commands . 154 Table 78 T1.317 Call-Back Security Related Commands . 154 Table 79 T1.317 Mid-String Voltage Related Commands . 154 Table 80 T1.317 Network Settings Related Commands . 155 Table 81 T1.317 Auxiliary Network Settings Related Commands . 155 Table C-1 Supported Battery Types . 169 Table D-1 Standard Configuration Item Defaults . 172 Table D-2 24V Battery Related Items Defaults . 183 Table D-3 48V Battery Related Items Defaults . 184 Issue 7 December 2011 7

Pulsar Plus Controller Family This page is intentionally blank. Issue 7 December 2011 8

Pulsar Plus Controller Family

Introduction

Pulsar Plus Family Controllers

Overview

The Pulsar Plus family of controllers is comprised of the Pulsar Plus, Pulsar Edge, and Phoenix controllers.

This manual covers the Pulsar Plus and Phoenix controllers. These controllers were developed for both indoor and outdoor cabinet power applications.

Modular hardware and software design of the controllers allow for easy customization for specific applications.

Controllers provide control and alarm monitoring functions over several communication interfaces including a standard RS-485 digital serial interface that interconnects system rectifiers, converters, and other peripherals. Compatible rectifiers include NE, CP, NP, EP, IP, and 59X series.

Local and remote access is provided.

Features are factory configured to industry standard defaults to minimize the setup process in the field.

Customer specified factory default configuration is also available.

Key Features

• Modular design allows different packaging alternatives: a single power slot positions of the rectifier

shelf, mounting to a cabinet or distribution door, and 1U rack-mount option • Easily field replaceable • Standard or customer specific factory defaults supported • Support of more than one factory default • Supports dual voltage plants, with rectifiers and converters • Auto -sensing dual voltage (both voltages and both currents displayed on front panel) • Power Unit control and management • Centralized settings for converter and rectifier output set-point voltages. • Up to 60 NE power modules (Rectifiers and converters) • Up to 32 CP rectifiers • Extensive Battery Management features • Management of four independent Low Voltage Disconnects (LVDs)

 Up to eight contactors can be assigned to contactor interface IDs  Load disconnects operated by low voltage, low voltage and/or time delay, remote command, or

external control signal  Battery disconnect operated by voltage threshold, voltage threshold and/or time, remote command, high battery temperature, or Emergency Power Off (EPO) signal • Battery recharge current limit feature • Low and high temperature voltage compensation  Independent adjustable slopes Issue 7 December 2011 9

Pulsar Plus Controller Family  Step function • Manual and automatic Boost charging • Manual, remote test, and periodic discharge test capability

 Reserve time calculations with configurable threshold  Manual time threshold for pass/fail criteria

• 1-Wire monitoring

 Up to six ES771 Mid-string voltage monitors (configurable mid-string imbalance alarm)  Up to sixteen battery thermal probes (configurable temperature alarm)

• Alarm management of 24V and 48V DC distribution • User defined thresholds • Front accessible 64x128 LCD with control pad and intuitive menu navigation system • Available front panel PIN (password) access feature • Alarm severity sensitive display back -light (LEDs on Phoenix controllers) • Voltage Test Jacks for both DC busses • Three separate configurable assignable LED indicators (18 on Phoenix controllers) • Built -in audible alarm and test feature • 10 configurable alarm outputs with manual alarm test features • 10 configurable binary inputs • Integrated 10/100Base -T Ethernet for local port or for Network remote monitoring • SNMP, TCP/IP, SMTP, HTTP, Telnet, FTP, and utilizes Dynamic Host Configuration Protocol (DHCP) • Compatible with standard browsers (MS Internet Explorer) • Event history log • Rectifier Group Standby/ Hold -off mapping (generator/AC load minimization) Issue 7 December 2011 10

Pulsar Plus Controller Family

Applications

The Pulsar Plus controller family has applications in Infinity NE, Infinity P2, the Compact Power (CP) Line, EPS, and previous generation power systems. Following are product depictions utilizing the various configurations of the controller. These applications utilize the NE843A slot controller and the NE843C, NE843E, and NE843P door/panel mounted controllers. Consult appropriate system manuals, technical field support or your local sales representative for more details on these or other power systems.